  • 10 Fully Programmable Zones
  • Remote LCD or LED Keypad
  • 4 Access Level Codes
  • 2 Part Guard Arming Options
  • LCD Keypad With 250 Event Memory LED Keypad With 16 Event Memory
  • Non-Volatile Memory
  • Programmable Timer For Entry/Exit & Bell Cut-Off
  • Battery Capacitor Up To 12V 2.2Ah
  • Simple To Install & Easy To Program
  • Up To 4 Remote Keypads

General Specifications
Zones 10 programmable zones, negative loop
Arming/Disarming Through remote LED Keypad, Through remote LCD Keypad
Alarm Memory LED keypad 16 events, LCD keypad 250 events
Walk Test Visual & audible on all zones
On Board Display Light emitting diodes (LED)
Protection Class Class I
Programme Timers
Full guard entry/exit delay 1 second - 15 minutes
Part guard exit delay 1 second - 15 minutes
Siren duration 3, 5 or 15 minutes
Programmable Functions
Full guard & 2 x part guard
10 fully programmable zones
Timed entry/exit, walk through, instant personal alarm, tamper, fire, secure final set, double knock, disable/Isolate
Codes 4 user, 1 engineer
Quick set facility
Engineer reset
Push button final set
Installer message displayed on LCD keypad
Zone location names on LCD keypad
Time & date displayed on LCD keypad
European Standards
Conforms to European law (EU) Low Voltage Directives LVD 73/23/EEC (amended 93/68/EEC) and Electro-magnetic Compatibility (EMC) 89/336/EEC (Amended by 92/31/EEC and 93/68EEC) RoHS
Power Supply
Primary mains supply voltage rating 230Vac
Maximum current rating 1000mA
Rechargeable backup battery 12Vdc
Environmental Specifications
Operating Temperature -0ºC - + 40ºC
Storage temperature -20ºC - + 60ºC
Maximum humidity 95% non-condensing
EMC environment Residential/Commercial
Physical Specifications
Dimensions 253mm X 195mm X 61mm
Housing material ABS
LCD Remote Keypad
Display 16 X 2 backlit LCD
Operating Voltage 12Vdc
Standby 60mA
In alarm 100mA
LED Remote Keypad
Operating Voltage 12Vdc
Standby 40mA
In alarm 70mA
Electrical Specifications
Quiescent current 50mA
Alarm Current 100mA
Set + output When low: 1.0Vdc, when high 12Vdc
Switched positive voltage When low: 1.0Vdc, When high 12Vdc
Bell voltage output 12Vdc
External speaker voltage output 12Vdc 16ohm, max Current: 220mA
Strobe voltage output 12Vdc latching
Positive loop threshold (zones1-7/tamper) Minimum open resistance: 70K, Maximum closed resistance: 10K
Negative loop threshold Zones 1-10