2 Wire Alarm Panels

LS800S Two-Wire Alarm Panel


LY52-038-47

The LS800S alarm panel is both easy to install and operate. It incorporates our patented 2 wire technology and the latest infrared design to ensure no false alarms through incorrect operation or installation.

No complicated user key buttons, all functions are operated by the coded remote key fobs. These employ anti grabbing codes and up to 8 can be individually programmed into the panel.

There are 8 alarm zones; 3 magnetic contacts and 5 intruder zones providing ample security features. Including a remote personal attack alarm and 24hr tamper detection this panel is sufficient for most if not all domestic environments.

This panel should be considered in conjunction with the 2 wire PIR’s, 2 wire magnetic contacts, 2 wire dialler and either the 2 wire bellbox (LY52-011-36), the Vortex II bellbox (LY52-055-48) or the solar bellbox (LY52-050-43) to provide complete flexibility.

General Specifications
Control Panel Specifications 8 pre-programmed zones
Arming/Disarming Using remote infrared key fob, maximum 8 per system.
Pre-programmed Zone Types Instant, delay, delay follower, omitted
Programmable Functions Adding additional infrared remote key fobs.
Walk Test Zones 1-8, tamper, PA, mains power, battery in use, day/off, part arm, learn
Panel LED Indicators Instant, delay, delay follower, omitted
Environmental Specification
Operating Temperature -0ºC - + 40ºC
Storage temperature -20ºC - + 60ºC
Maximum humidity 95% non-condensing
Power Supply Adaptor
Primary mains supply 230Vac, 50Hz
Secondary 16Vac
Mains Fuse 3 Amp 250V
Battery back up 1.3 - 2.2Ah 12vdc sealed lead acid battery
Programmable & Fixed Timers
Entry delay 15 or 30 seconds
Exit delay 30 seconds
Siren duration 20 minutes
Physical Specification
Dimensions 285mm X 210mm X 60mm
Housing material ABS
European Standards
Conforms to European law (EU) Low Voltage Directives LVD 73/23/EEC (amended 93/68/EEC) and Electro-magnetic Compatibility (EMC) 89/336/EEC (Amended by 92/31/EEC and 93/68EEC) RoHS
Electrical Specification
Current consumption Quiescent: 100mA, In alarm: 550mA
Auxiliary voltage output 13Vdc
Siren/strobe voltage output 12Vdc
Set output OV day/off, 12Vdc armed
Battery charge voltage 13.8Vdc
Voice dialler trigger output 5V normal, 0V triggered