Sealed Lead Acid Batteries

12V 1.3AH Sealed Lead Acid Battery


LY11-042-19

  • The 'Online' range of sealed lead acid batteries are maintenance free, valve regulated and leak proof ideally suited to all 'standby applications'
  • There will be no loss in power output over the battery life.
  • Low self-discharge of about 2-3% per month compared with 20-30% for more common battery systems.
  • Quality construction with no compromise on materials to ensure a long service life.
  • Low internal resistance means a high discharge rate.
  • Wide operating temperature range operating between -15° C to +50 ° C when fully charged.

Specifications
Nominal Voltage 12V
Rated Cap 1.3AH
Approx Weight 0.57kg
Terminal Standard F3-TAB 187E
Optional
Operation Temperature
Charge 0°C (32°F) - 40°C (104°F)
Discharge -20°C (-4°F) - 50°C (122°F)
Storage -20°C (-4°F) - 40°C (104°F)
Capacity 25° (77°F) 20 hour rate (0.165A) 1.3AH
10 hour rate (0.297A) 1.17AH
5 hour rate (0.528A) 1.04AH
1 hour rate (1.98A) 0.78AH
Capacity affected by temperature 40°C (104°F) 103%
25°C (77°F) 100%
0°C (32°F) 86%
-15°C (5°F) 65%
Self-Discharge at 25ºC (77ºF) (Before recharge) Capacity after 3 month 91%
Capacity after 6 month 82%
Capacity after 12 month 64%
Constant voltage charge Cycle Initial Charging Current ≤0.39A 14.4V - 15V at 25°C (77°F)
Standby 13.5V - 13.8V at 25°C (77°F)
Max discharge current for 5 secretary 19.5A
Dimensions(mm)
Specifications
Time (mm) 5 10 15 20 30 60 120 180 300 600
Final voltage
1.80VPC A 4.48 2.69 2.06 1.75 1.05 0.71 0.25 0.23 0.08 0.06
W 47 28.2 21.6 18.2 11 6.2 2.6 1.6 0.8 1.15
1.75VPC A 4.76 2.99 2.19 1.92 1.2 0.78 0.32 0.28 0.11 0.07
W 50 31.4 23 20.2 12.6 7.6 3.4 2.4 1.2 1.25
1.70VPC A 4.95 3.14 2.38 2 1.31 0.82 0.38 0.32 0.15 0.11
W 52 33 25 21 13.8 8.2 4 3 1.6 1.3
1.65VPC A 5.14 3.28 2.48 2.1 1.39 0.86 0.44 0.34 0.18 0.15
W 54 34.2 26 22 14.6 9 4.6 3.6 2.1 1.4
1.60VPC A 5.35 3.47 2.6 2.18 1.5 0.93 0.53 0.39 0.21 0.18
W 56.1 36.4 27.3 22.88 15.74 9.72 5.6 4.14 2.7 1.5
Discharge Characteristics

Note: Discharge shall be cut-off at 10.5V if discharge at <1CA and at 9.6V if at ≥1CA It is recommended to recharge battery by constant-voltage charge immediately after use.

Applications
  • Lighting Equipment
  • Emergency Lighting
  • Toys & Consumer Electronics
  • Fire Alarm & Security Systems